Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - YARD WTR LINE/TEST
Permit Number - T05CM04248
Inspection Description - PLUMBING - YARD WTR LINE/TEST
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/28/2007 | PLUMBING - YARD WTR LINE/TEST | Approved | IVRS - Inspection :* | |
03/22/2007 | PLUMBING - YARD WTR LINE/TEST | Partial Approval | IVRS - Inspection :* 1. 4" RP OK TO COVER 2. 1 1/2 IRRIGATION ASSEMBLY IS REQUIRED TO BE 12" ABOVE GRADE. ALSO, WATER TO ASSEMBLY SHALL BE ON FOR INSPECTION. MUSHROOM ON FORM STAKE MAY DAMAGE COPPER. YOU MAY COVER ON STREAM RISER FOR SUPPORT. |
|
03/19/2007 | PLUMBING - YARD WTR LINE/TEST | Not ready for Inspection | IVRS - Inspection :* ASSEMBLY, THRUST BLOCK AND IRRIGATION CONNECTION LEAK OK, WATER NEEDS TO BE ON FOR INSPECTION. SECURE TRACER WIRE ABOVE GRADE |
|
03/16/2007 | PLUMBING - YARD WTR LINE/TEST | Not ready for Inspection | IVRS - Inspection :* | |
03/15/2007 | PLUMBING - YARD WTR LINE/TEST | Denied | IVRS - Inspection : See detailed listing on site.| 999* RPA REQUIRED ON DOMESTIC WATER SUPPLY. DETAIL ON P4 THRUST BLOCKS REQUIRED IRRIGATION CONNECTION SHALL BE DOWN STREAM OF MAIN BACKFLOW ASSEMBLY. SADDLE TAPS ON NEW PIPING ARE NOT ACCEPTED. |
|
02/28/2007 | PLUMBING - YARD WTR LINE/TEST | Partial Approval | IVRS - Inspection :* CONNECTION AT BUILDING OK TO COVER |
|
02/01/2007 | PLUMBING - YARD WTR LINE/TEST | Partial Approval | IVRS - Inspection :* 1) 4" PVC YARD WATER WITH 200 PSI TEST CAPPED AT EACH END OK 2) NEED TO SEE FINAL CONNECTIONS AT BLDG, METERS AND RPS |
|
01/31/2007 | PLUMBING - YARD WTR LINE/TEST | Partial Approval | IVRS - Inspection :* 1. TEST NOT READY. PIPING OK 2. OK TO COVER PIPING IN DRIVE IF NEEDED; CONTINGENT TO APPROVAL OF PRESSURE TEST. 3. RECALL FOR PRESSURE TEST. |
|
01/30/2007 | PLUMBING - YARD WTR LINE/TEST | Not ready for Inspection | IVRS - Inspection :* | |
01/26/2007 | PLUMBING - YARD WTR LINE/TEST | Not ready for Inspection | IVRS - Inspection :* | |
11/06/2006 | PLUMBING - YARD WTR LINE/TEST | Not ready for Inspection | IVRS - Inspection :* |