Permit: T05CM04248

Parcel: 110121020


Addresses:

2715 N WYATT DR


Inspection Status: Approved

Inspection History: PLUMBING - YARD WTR LINE/TEST

Permit Number - T05CM04248

Inspection Description - PLUMBING - YARD WTR LINE/TEST

Inspection Status - Approved

Date Description Inspector Results Comments
03/28/2007 PLUMBING - YARD WTR LINE/TEST Approved IVRS - Inspection :*
03/22/2007 PLUMBING - YARD WTR LINE/TEST Partial Approval IVRS - Inspection :*
1. 4" RP OK TO COVER
2. 1 1/2 IRRIGATION ASSEMBLY IS REQUIRED TO BE 12" ABOVE GRADE. ALSO, WATER TO ASSEMBLY SHALL BE ON FOR INSPECTION. MUSHROOM ON FORM STAKE MAY DAMAGE COPPER. YOU MAY COVER ON STREAM RISER FOR SUPPORT.
03/19/2007 PLUMBING - YARD WTR LINE/TEST Not ready for Inspection IVRS - Inspection :*
ASSEMBLY, THRUST BLOCK AND IRRIGATION CONNECTION LEAK OK, WATER NEEDS TO BE ON FOR INSPECTION.
SECURE TRACER WIRE ABOVE GRADE
03/16/2007 PLUMBING - YARD WTR LINE/TEST Not ready for Inspection IVRS - Inspection :*
03/15/2007 PLUMBING - YARD WTR LINE/TEST Denied IVRS - Inspection :
See detailed listing on site.| 999*
RPA REQUIRED ON DOMESTIC WATER SUPPLY. DETAIL ON P4
THRUST BLOCKS REQUIRED
IRRIGATION CONNECTION SHALL BE DOWN STREAM OF MAIN BACKFLOW ASSEMBLY. SADDLE TAPS ON NEW PIPING ARE NOT ACCEPTED.
02/28/2007 PLUMBING - YARD WTR LINE/TEST Partial Approval IVRS - Inspection :*
CONNECTION AT BUILDING OK TO COVER
02/01/2007 PLUMBING - YARD WTR LINE/TEST Partial Approval IVRS - Inspection :*
1) 4" PVC YARD WATER WITH 200 PSI TEST CAPPED AT EACH END OK
2) NEED TO SEE FINAL CONNECTIONS AT BLDG, METERS AND RPS
01/31/2007 PLUMBING - YARD WTR LINE/TEST Partial Approval IVRS - Inspection :*
1. TEST NOT READY. PIPING OK
2. OK TO COVER PIPING IN DRIVE IF NEEDED; CONTINGENT TO APPROVAL OF PRESSURE TEST.
3. RECALL FOR PRESSURE TEST.
01/30/2007 PLUMBING - YARD WTR LINE/TEST Not ready for Inspection IVRS - Inspection :*
01/26/2007 PLUMBING - YARD WTR LINE/TEST Not ready for Inspection IVRS - Inspection :*
11/06/2006 PLUMBING - YARD WTR LINE/TEST Not ready for Inspection IVRS - Inspection :*