Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
Permit Number - T05CM04248
Inspection Description - PLUMBING - ROUGH, SOIL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/26/2006 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection :* | |
09/22/2006 | PLUMBING - ROUGH, SOIL | Partial Approval | - CORRECT SLOPE ON NS WASTE AT TOILET RM 8 LOCATION OK TO POUR AFTER CORRECTING. - ALL AREAS EXCEPT SOUTHEAST CORNER OF BUILDING. - I RECOMMEND WATER TESTING ALL BUILDING DRAIN PIPING AGAIN BECAUSE OF SHOWER FORM STAKES PROXIMITY TO SINK PIPING. |
|
09/19/2006 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* UNDERGROUND PIPING OK TO COVER RECALL UNDERGROUND INSPECTION FOR PRE-SLAB |
|
09/18/2006 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* SOIL PIPING ALONG M.3, TRS 62, 63, 55, 56 OK TO COVER |
|
09/15/2006 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* ROUGH PIPING RMS 34-36 AND MAIN LINE THROUGH END OF LINE C.O OK TO COVER. PIPE WRAPS IN FOOTING OK 4" CW W/BRAZED JOINT 98 PSI TEST PROTECT FROM CONCRETE |
|
09/14/2006 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* RMS 27, 24, 25, 31 AND 32 OK TO COVER |
|
09/12/2006 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* - TOILET RM 8, 9, 15 AND 1 - CORRECT SLOPE AT NS WASTE AND SH TRAP ARM IN TR8 - OK TO COVER AFTER CORRECTING. |
|
09/08/2006 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* PRE-SLAB SEC. A-F PIPE WRAPS OK FDS W/PRIMERS INSTALLED SHOWER DRAINS INSTALLED |
|
09/05/2006 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* SEC A-C OK TO COVER NEED TO SEE FDS AND PIPE WRAPS BEFORE CONCRETE. |
|
09/01/2006 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* ABS DWV COL LINES C-F OK TO COVER CALL FOR PRE-SLAB PRIOR TO CONCRETE. |
|
08/31/2006 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* RESTROOM AREAS DRAIN TO BE UPSIZED AT LAV BECAUSE PLAN IS APPROVED IN ERROR TO 3" ALL PIPING TO BE SHADED CORRECTLY. DELTA 3 REVISION DATED 8/15/06 SERVING AS REDLINE ON SITE. PLEASE RED LINE UP SIZE ON YOUR PLAN. |