Permit: T05CM04248

Parcel: 110121020


Addresses:

2715 N WYATT DR


Inspection Status: Approved

Inspection History: ELECTRIC - UNDERGROUND

Permit Number - T05CM04248

Inspection Description - ELECTRIC - UNDERGROUND

Inspection Status - Approved

Date Description Inspector Results Comments
04/16/2007 ELECTRIC - UNDERGROUND Approved IVRS - Inspection :*
01/12/2007 ELECTRIC - UNDERGROUND Partial Approval IVRS - Inspection :*
12/29/2006 ELECTRIC - UNDERGROUND Partial Approval IVRS - Inspection :*
OK 3 POLE BASES AND CONDUIT POLE TO POLE SOUTH
12/28/2006 ELECTRIC - UNDERGROUND Not ready for Inspection IVRS - Inspection :*
1) UNDERWATER-CANCELLED
12/26/2006 ELECTRIC - UNDERGROUND Partial Approval IVRS - Inspection :*
OK PVC CONDUITS POLE TO POLE
AND TO JUNCTION BOXES NORTH & EAST
12/21/2006 ELECTRIC - UNDERGROUND Partial Approval IVRS - Inspection :*
11/06/2006 ELECTRIC - UNDERGROUND Partial Approval IVRS - Inspection :*
10/24/2006 ELECTRIC - UNDERGROUND Partial Approval IVRS - Inspection :*
UG NORTH PORTICHERE AREA
10/20/2006 ELECTRIC - UNDERGROUND Partial Approval IVRS - Inspection :*
STUB UPS AT COLUMNS 4.7
C9 & D7 (RIGID 90'S)

UG RIGID 90'S
CONCRETE @ 10:30
240-6403
10/05/2006 ELECTRIC - UNDERGROUND Partial Approval IVRS - Inspection :*
09/27/2006 ELECTRIC - UNDERGROUND Partial Approval IVRS - Inspection :*
OK PVC CONDUIT EXTENSIONS TO ELECTRIC ROOM UNDER SLAB
09/21/2006 ELECTRIC - UNDERGROUND Partial Approval IVRS - Inspection :*
OK PVC CONDUITS UNDER SLAB
FOR FLOOR BOX -- NURSES STATION AND RUNS TO OUTSIDE
LIGHTING AND COMMUNICATIONS EXCEPT TO ELECTRIC ROOM
09/19/2006 ELECTRIC - UNDERGROUND Partial Approval IVRS - Inspection :*
OK 6-PVC FEEDERS COL "F" BACK TO ELECTRIC ROOM.
09/13/2006 ELECTRIC - UNDERGROUND Partial Approval IVRS - Inspection :*
- OK PVC CONDUITS UNDER ELECTRIC ROOM
- OK 2 FEEDERS CONTINUATION FROM COL. "F" TO COL. "J"
09/08/2006 ELECTRIC - UNDERGROUND Partial Approval IVRS - Inspection :*
OK FEEDERS NL4A & EL4A TO COLUMN "F"
09/07/2006 ELECTRIC - UNDERGROUND Not ready for Inspection IVRS - Inspection :*
CANCELLED RAIN DELAY
09/06/2006 ELECTRIC - UNDERGROUND Partial Approval IVRS - Inspection :*
OK FEEDER CONDUIT UNDER ELECTRIC ROOM
OK 6 - 4" PVC DATA UNDER SLAB
08/25/2006 ELECTRIC - UNDERGROUND Partial Approval IVRS - Inspection :*
OK 2 - 4" PVC 60' DATA
OK 3 - 4" PVC 10' FEEDER
OK 4 - 2 1/2" PVC 15' FEEDER
OK 3 - 1" PVC 15' TO EAST