Inspection History Details
Inspection Status: Approved
Inspection History: EXCAVATION/LAYOUT REBAR & ZON
Permit Number - T05CM04248
Inspection Description - EXCAVATION/LAYOUT REBAR & ZON
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/30/2007 | EXCAVATION/LAYOUT REBAR & ZON | Approved | IVRS - Inspection :* | |
02/07/2007 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* 1) SCREEN WALL C/5.8 TO C/6.8 AT 8' SCREEN WALLS C.4/6.8 TO D.5/7.7 AT 48" TO 7'-8"; SCREEN WALLS F/6.7 TO J.3/7.7 48" TO 7'-8"; GENERATOR ENCLOSURE PERIMETER WALLS AT 48" 2) OK TO POUR 3) CONCRETE SPILL WAY AT N.E. CORNER AS PER DETAIL #10-C303 4) SCREEN WALL FOOTING-LINE B.4/4-6 C.2/4-6 (DONOR WALL) 5) TRASH BIN FOOTINGS-OK TO POUR |
|
01/30/2007 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* FOOTINGS FOR GENERATOR PAD/FOUNDATIONS SITE WALLS @ SE ENTRY (7'4") |
|
01/24/2007 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* SOUTH PORCHES - OK TO POUR FOOTINGS |
|
01/12/2007 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* SCREEN WALL F/4.3 TO F/4.6; K/4.6 TO L.5/4 OK TO POUR FOOTINGS |
|
12/21/2006 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* 8 @ 6' LIGHT POLE CAISSONS; NW SPILL WAY - OK TO POUR |
|
12/20/2006 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* WATER RETENTION BASIN HEAD WALL FOUNDATION -- OK TO POUR |
|
10/31/2006 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* APPROX. 400' OF SITE WALL @ NORTH END OF PROPERTY LINE AS PER DETAIL B/304 -- OK TO POUR |
|
10/26/2006 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* 6 @ F4 FOOTINGS @ C.9/1 TO 4.9 & D.7/1 TO 4.9, 1 @ F3 @ G.2/4 |
|
10/25/2006 | EXCAVATION/LAYOUT REBAR & ZON | Denied | IVRS - Inspection : See detailed listing on site.| 999* FOUNDATION OR FOOTING UNDER WATER FOOTING NEEDS TO BE DRY ACCORDING WITH SEC. 109 IBC |
|
10/23/2006 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* COLUMNS @ D.2/7, D.7/4.4; E.4/4.8, 4.4, 5.2, 5.6 OK TO POUR |
|
10/20/2006 | EXCAVATION/LAYOUT REBAR & ZON | Not ready for Inspection | IVRS - Inspection :* CONTRACTOR CANCELLED |
|
10/05/2006 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* 4 @ COLUMN FOOTINGS @ B.1/4.7 TO B.8/4.7; 6 @ COLUMN FOOTINGS @ C.9/1 TO C.9/4.9 & D.7/1 TO D.7/4.9 3 @ COLUMN FOOTINGS @ P/4.4 TO P/5.2 |
|
09/18/2006 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* F1 FOOTING AS PER 8/31/06 INSPECTION REQUEST OK TO POUR |
|
08/31/2006 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* F1 FOOTINGS SE QUAD -- PLEASE BLOCK OUT ELEC. ROOM SO WE CAN SEE CONDUIT. |
|
08/29/2006 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* F1 AND F3 FOOTINGS (NO F2 MASONRY) OK FOR NE QUADRANT LINE F & LINE 5.5 AND QUAD LINES |
|
08/25/2006 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* WEST PORTION OF BUILDING, LINES G/8 THROUGH F/4.3 OK TO POUR EXTERIOR/INTERIOR FOOTINGS. |