Permit: T05CM04226

Parcel: 126210240

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T05CM04226

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
08/03/2006 FRAMING Approved IVRS - Inspection :*
07/31/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
A. APPROVED TO INSULATE WALLS ONLY
B.
1. ANTI-SIPHON ON HOSE BIBS
2. SLEEVE CONDUCTORS THAT PASS THROUGH MASONRY WALLS.
3. FIREBLOCK @ CAT-5 WIRING IN GARAGE
4. APPROVED FIRESTOP REQUIRED BETWEEN FRAMING & MASONRY @ CEILING.
5. STAPLE WIRES 8" FROM BOX @ CORNER OF KITCHEN.
6. SEPARATE ALL WIRES FROM TRUSS GANG PLATES
7. FIRESTOP FLOOR/CEILING PENETRATIONS
8. CLEANOUT REQ'D 2ND FLOOR
9. FLUE @ FURNACE?
10. PROVIDE TRUSS SPECS
11. BLOCK DROP CEILINGS
12. CLIP STUDS UNDER STAIR STRINGER 4' OC
13. STOPPED INSPECTIONS
07/20/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) COMPLY WITH ALL ITEMS FROM PREVIOUS INSPECTION
2) STOPPED INSPECTION
07/18/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) DRYER VENT BROKEN ABOVE 1ST FLOOR CEILING
2) A/C LINE SCRAPING ON FHA STRAP SOUTH WALL GARAGE
3) SEAL PENETRATION IN 2ND FLOOR
4) ROMEX NORTH WALL GARAGE CEILING PINCHED IN TRUSSES
5) REAR DOOR ROMEX ? AT SWITCH BOX
6) MOVE COMBUSTIBLES AWAY FROM CAN LIGHTS
7) BLOCKING IN KITCHEN SOUTH WALL PINCHING WIRES
8) 2ND FLOOR NORTH WALL CEILING WIRES PINCHED IN COILING
9) STOPPED INSPECTION