Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T05CM04208

Parcel: 125151110


Addresses:

55 E CALLE BELLEZA


Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T05CM04208

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
02/07/2006 FRAMING Approved IVRS - Inspection :*
02/03/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) FIREBLOCK DROPPED CEILINGS
2) WIRE MUST TERMINATE IN CANS
3) SECURE ROMEX 8" FROM BOXES
4) FIREBLOCK ENTRY
5) SHIM HEADERS
6) INSTALL SMOKE DETECTORS IN BEDROOM 1 IN HALLWAY