Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T05CM04202
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/09/2005 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
11/07/2005 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) CO2 BV TRUSSES MISSING BRACING PER TRUSS DRAWINGS 2) 3/8" OSB BRACED WALL PANELS NOT INSTALLED PER IRC SECTION R602.10.3 SUB PARAGRAPH 3 AND TABLE 602.3 (3) NOTE B 3) PLANS CALL FOR STRUCTURAL #11 PLYWOOD WITH PANELS ACROSS STUDS. #1 USED VERTICAL SEE NOTE 6 SHEAR SCHEDULE 4) NO ACCESS TO ROOF 5) STOPPED INSPECTION |