Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T05CM04180

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
12/07/2005 FRAMING Approved IVRS - Inspection :*
11/30/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) ENTRY WINDOW (ABOVE) NOT LATH, INTERIOR LATH SEALED
2) WATER LINES NOT PRESSURIZED
3) DWV'S OK
11/29/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) LATH NOT FINISHED UNDER FRONT PORCH WINDOW
2) WATER LINES NOT PRESSURIZED
3) SECURE WATER LINES AT LAUNDRY ROOM
4) SEAL LATH FROM INSIDE
5) LOOSE ANCHOR BOLTS THROUGHOUT
6) USE PROPER NAIL PROTECTION FOR WATER LINES AT KITCHEN
7) NAIL PROTECT ELECTRIC WIRE AT KITCHEN TOP PLATE
8) SHIM HEADERS WHERE NEEDED
9) STOPPED INSPECTION-TOO MANY ITEMS