Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: STUCCO MESH
Permit Number - T05CM04173
Inspection Description - STUCCO MESH
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/31/2006 | STUCCO MESH | Approved | IVRS - Inspection :* | |
03/28/2006 | STUCCO MESH | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NEED APPROVED TRUSS DRAWINGS 2) SECURE ELECTRIC WIRES AWAY FROM FLUE PIPES 3) NO H20 TEST DWV 4) INSTALL BANG PLATE NAIL PROTECTION ELECTRIC/PLUMBING THROUGHOUT 5) STRAP HEADERS AT BEARING 6) GAS TEST HOLDING 30 POUND TEST 7) I-JOISTS DON'T MATCH PLAN 8) CLIP INTERIOR BEARING WALLS ACCORDINGLY AND BOLTS 9) STOPPED INSPECTION |
|
03/27/2006 | STUCCO MESH | Not ready for Inspection | IVRS - Inspection :* |