Permit: T05CM04163

Parcel: 112043590


Addresses:

2921 E LA MADERA DR

Inspection Status: Partial Approval

Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
05/24/2006 BUILDING - FINAL Partial Approval IVRS - Inspection :*
1) PENDING CERTS
05/09/2006 BUILDING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) B-VENTS NEEDS MORE VERTICAL ANGLE/WATER HEATER & HEATER
2) BEDROOM ARC FAULTS NOT WORKING
3) NO ADDRESS POSTED
4) NO DRIP LINE ON GAS-MECHANICAL W/H & HEATER
05/05/2006 BUILDING - FINAL Denied NO ONE HOME
04/26/2006 BUILDING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) SMOKE DETECTOR REQUIRED IN BEDROOM HALLWAY
2) WATER HEATER CONTROL NOT ACCESSIBLE
3) OUTISDE GFI DOESN'T TEST
4) NO COVER DISPOSAL RECEPTACLE
5) OPEN GROUND RECEPTACLE S.E. BEDROOM
6) OPEN BULBS NOT PERMITTED IN CLOSETS
7) BATHROOM GFI INOPERABLE-DOES NOT TEST
8) SMOKE DETECTORS TO BE ARC FAULT
9) UNABEL TO LOCATE WATER BOND