Permit: T05CM04158

Parcel: 140378480

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
12/12/2005 FRAMING Approved IVRS - Inspection :*
12/08/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NORTH SHEARWALL REQUIRES ANCHOR BOLTS AT 16" ON CENTER
12/06/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) CLIP INTERIOR BEARING WALL AT GARAGE
2) DBL STUD UNDER BEAM IN GARAGE
3) PROTECT WIRES FROM FLOOR TRUSS GANG PLATE AT WATER HEATER
4) SMALL APPLIANCE CIRCUIT SHARES L.R. CIRCUIT
5) PROTECT CONDENSATE DRAIN AT KITCHEN
6) WATER AROUND AB'S AT UTILITY