Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/01/2005 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 11/08/2005 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1) NO PERMIT ON SITE |
|
| 11/04/2005 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : A reinspection fee has been assessed for this inspection. Multiple inspection Refee P-1 shearwall not nailed per plan at entry below window |
|
| 11/02/2005 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NO CHANGE |
|
| 11/01/2005 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) P-1 SHEARWALL AND RIBBON NOT NAILED ABOVE ENTRY |
|
| 10/25/2005 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) 3/8" OSB SHEAR PANELS MUST BE INSTALLED WITH LONG DIMENTION ACCROSS STUDS 2000 IRC TABLE 602.3 (3) NOTE B 2) P-1 SHEAR WALL NOT NAILED ABOVE ENTRY 3) NAIL PROTECT PLUMBING WITHIN 1 1/4" OF PLATE SURFACE |