Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T05CM04133
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/20/2005 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* | |
| 10/14/2005 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :*SECURE CLOSET FLANGES TO THE FLOOR A BLAKE TEE IS LISTED TO BE USED IN A VERTICAL POSITION ABOVE CEILING OK TO COVER. |
|
| 10/10/2005 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* NOT READY I WANT TO SEE THE MOP SINK COMPLETED. |
|
| 10/06/2005 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* | |
| 09/29/2005 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* OK TO COVER ALL AREAS NEED TO SEE CLOSET FLANGES |
|
| 09/23/2005 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* | |
| 09/21/2005 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* | |
| 09/20/2005 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) ALL VERTICAL PIPING TO HAVE MID STORY SUPPORT ALL OVERHEAD PIPING TO BE SUPPORTED AT EACH CHANGE OF DIRECTION OR ELEVATION AND AT THEN END OF BRANCHES, THE NO MORE THAN FOUR FEET BETWEEN HANGERS |
|
| 09/06/2005 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* 1) REVISED APPROVED PLAN ON SITE 2) PVC DWV UNDERGROUND OK TO COVER 3) WOULD LIKE TO SEE MANUFACTURER INSTALLATION MANUAL SHOWING FLOW CONTROL INSTALLATION 4) OK TO COVER ALL AREAS |
|
| 09/02/2005 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* 1) NO REVISED PLAN ON SITE-RED LINES WON'T SUFFICE 2) MAKE SURE THE ACCURATE REVISED APPROVED PLAN IS ON SITE, OR HAVE CLEAR RED LINES 3) OK TO COVER UNDERGROUND EXCEPT FOR WATER CLOSETS AND ONE FLOOR SINK VENT 4) FLOW CONTROL NOT IN READILY ACCESSIBLE AND VISIBLE LOCATION TO BE REMOVED |