Permit: T05CM04129

Parcel: 118082040

Inspection Status: Denied

Inspection History: FRAMING

Permit Number - T05CM04129

Inspection Description - FRAMING

Inspection Status - Denied

Date Description Inspector Results Comments
11/16/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
11/16/2005 FRAMING Approved IVRS - Inspection :*
11/15/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) PROVIDE ENGINEER REPORT ON DAMAGED TRUSSES IN GARAGE
2) COMPLETE NAILING ON H.D. SOUTHWEST END OF GARAGE
3) SUPPORT BOTH ENDS OF 4 GANG SWITCH BOX IN HALL
4) BLOCK 3 SIDES OF HVAC BOOT IN HALL
5) PROTECT PLUMBING AT BOTTOM PLATE IN MASTER BATH
6) SUPPORT VENT 90 TO ROOF IN MASTER BATH
7) KITCHEN PLUMBING OUT OF WALL FIX AND RESEAL LATH
11/02/2005 FRAMING Partial Approval 1) ADD STUDS OVER WEST WALL WINDOWS FOR 16" ON CENTER AT FRAME