Permit: T05CM04126

Parcel: 140378190


Addresses:

6781 S AQUILINE DR

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
12/01/2005 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
11/28/2005 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) GABLE END TRUSSES NOT CLIPPED PER 1/SD3
2) NAIL PROTECT PLUMBING WITHIN 1 1/4" OF PLATE SURFACES
3) P-1 SHEAR NOT NAILED
4) TEMPORARY BRACING MUST BE NAILED WITH 2 NAILS EACH END AND ONE PER STUD
5) PORCH ROOF NOT NAILED SOUTH END
6) ROOF SHEATHING MUST BE INSTALLED WITH GRAIN ACCROSS TRUSSES
7) MANY ROOF PANELS NOT NAILED
8) ROOF SHEATHING MUST SPAN 3 TRUSSES