Permit: T05CM04107

Parcel: 11508173B

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Permit Number - T05CM04107

Inspection Description - ELECTRIC - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
09/29/2005 ELECTRIC - FINAL Approved SUBJECT TO LAST INSPECTION. IVRS - Inspection :*
09/12/2005 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) ROOF-SUPPORT GUTTER, SEAL HOLES IN DISCONNECT, PROPERLY FUSE UNIT, RUNG GROUND IN FLEX, SUPPORT FLEX OF ROOF
2) FRONT O/S FIXTURES TO BE DAMP LOCATION APPROVED
3) CLOSE OFF OPEN BOXES SHOWING WIRING
4) SERVICES OK
09/09/2005 ELECTRIC - FINAL Partial Approval IVRS - Inspection :*
1) BOND NEUTRAL IN SERVICE DISCONNECTS
2) BOND BUSHING REQUIRED ON NIPPLES FOR UNPROTECTED SIDE OF SERVICE CONDUCTORS
3) INSTALL REJECTION PINS