Permit: T05CM04103

Parcel: 122163320


Addresses:

3555 E EDISON ST

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
01/25/2006 FRAMING Approved IVRS - Inspection :*
01/11/2006 FRAMING Partial Approval IVRS - Inspection :*
1) EXCEPT PORCH
01/10/2006 FRAMING Partial Approval IVRS - Inspection :*
1) EXCEPT FRONT PORCH
2) INSTALL H2.5 TOP AND BOTTOM KING STUD CABINET WALL AT REFRIDGERATOR
3) INSTALL H.25 AT TOP PLATE AT CABINET WALL AT REGRIDGERATOR ENTRY TO HALL. NAIL EVERY HOLE 3 STUDS OVER TOP H.25
4) OK TO INSULATE
5) RECALL FRAME FOR ABOVE ITEMS
01/09/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) INSTALL 2-2 X 4 AT MECHANICAL ROOM 4 X 12 HEADER
2) MISSING NUT GARAGE 2 X 6 BEARING WALL
3) RELOCATE SMOKE DETECTORS MINIMUM 36" CLEARANCE FROM SUPPLY REGISTER BEDROOM #3
4) MISSING H.25 CLIPS PER DETAIL 2/7
5) OVERNOTCH AT GAS LINE AT KITCHEN CABINET DLB TOP PLATE 2-18 GUAGE STRAPS
6) MAXIMUM 2 ROMEX PER STAPLE THROUGHOUT
7) COMPLY WITH DETAIL 3/7 1/2" GAP NEEDED BATHROOM WALL
8) NAIL PROTECT MASTER BEDROOM SOUTH WALL ROMEX
9) PROVIDE COPPER AND GAS BONDS
10) MISSING H2.5 AT GARAGE 2/7 WALL TOP PLATES
11) FRONT PORCH NOT COMPLETE