Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/25/2006 | FRAMING | Approved | IVRS - Inspection :* | |
| 01/11/2006 | FRAMING | Partial Approval | IVRS - Inspection :* 1) EXCEPT PORCH |
|
| 01/10/2006 | FRAMING | Partial Approval | IVRS - Inspection :* 1) EXCEPT FRONT PORCH 2) INSTALL H2.5 TOP AND BOTTOM KING STUD CABINET WALL AT REFRIDGERATOR 3) INSTALL H.25 AT TOP PLATE AT CABINET WALL AT REGRIDGERATOR ENTRY TO HALL. NAIL EVERY HOLE 3 STUDS OVER TOP H.25 4) OK TO INSULATE 5) RECALL FRAME FOR ABOVE ITEMS |
|
| 01/09/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) INSTALL 2-2 X 4 AT MECHANICAL ROOM 4 X 12 HEADER 2) MISSING NUT GARAGE 2 X 6 BEARING WALL 3) RELOCATE SMOKE DETECTORS MINIMUM 36" CLEARANCE FROM SUPPLY REGISTER BEDROOM #3 4) MISSING H.25 CLIPS PER DETAIL 2/7 5) OVERNOTCH AT GAS LINE AT KITCHEN CABINET DLB TOP PLATE 2-18 GUAGE STRAPS 6) MAXIMUM 2 ROMEX PER STAPLE THROUGHOUT 7) COMPLY WITH DETAIL 3/7 1/2" GAP NEEDED BATHROOM WALL 8) NAIL PROTECT MASTER BEDROOM SOUTH WALL ROMEX 9) PROVIDE COPPER AND GAS BONDS 10) MISSING H2.5 AT GARAGE 2/7 WALL TOP PLATES 11) FRONT PORCH NOT COMPLETE |