Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T05CM04084

Parcel: 140553230

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
10/07/2005 FRAMING Approved IVRS - Inspection :*
10/05/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) STRAP AT GARAGE BEAM POCKET
2) DBL STUD UNDER GIRDER AT ENTRY
3) AB AT WEST SIDE ENTRY
4) BLOCK HVAC BOOT AT UTILITY
5) SUPPORT ALL VENT 90'S TO ROOF
6) BANG PLATE AT LAUNDRY
7) FIRESTOP 2ND FLOOR PENETRATIONS
8) COMPLETE ALL HOLDOWNS
9) BANG PLATE PEX LINE AND ELECTRIC AT KICTHEN
10) TIGHTEN RED HEADS THROUGHOUT
11) BANG PLATE IN BATH
12) SHIM HEADERS WHERE NEEDED
13) SUPPORT STAIR STRINGER
14) STRAP TOP PLATE AT ENTRY
15) BLOCK CHASE IN 2ND FLOOR BATH
16) RELOCATE RECEPTACLES AT 2ND FLOOR BATH
17) COMPLETE STUCCO MESH AROUND WINDOW AND GABLE KNOCKOUT