Permit: T05CM04081

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
11/28/2005 FRAMING Approved IVRS - Inspection :*
1) ITEM 03050 NOT REQUIRED-NO GAS/ALL ELECTRIC
11/23/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
11/17/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NO PLAN/PERMIT
11/16/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NAIL PROTECT PLUMBING
2) FIREBLOCK TRIMMERS
3) CONDENSATE LINES HAVE NEGATIVE FLOW AND NOT CONNECTED
4) LEAD AT WASHER STAND PIPE
5) SHIM HEADERS WHERE NEEDED
6) SEE INSPECTION DATED 11/08/05
7) ITEM 03050 NOT REQUIRED-NO GAS/ALL ELECTRIC
11/08/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) WATER LINES NEED TO BE AT 50 PSI
2) FIREBLOCK GARAGE WALL TO HOUSE
3) NO SAFETY BARRIER F1 WATER HEATER
4) PROVIDE SPECIAL INSPECTION FOR SLAB JACK HAMMERED AT POWDER ROOM
5) BLOCK MECHANICAL 3 SIDES
6) WATER LEAK AT 3" ABS AT KITCHEN CEILING
7) SEAL PENETRATIONS FROM 1ST TO 2ND FLOOR
8) FIREBLOCK CHASE AT KITCHEN VENT
9) STOPPED INSPECTION