Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T05CM04080

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
10/21/2005 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
10/19/2005 EXT METAL CLIPS/EXT SHEATHING Denied 1) HOLDOWN SOUTH GARAGE WALL OVERSPALLED, 5 AT SOUTH WALL OF HOUSE, ONE EAST WALL
2) OVERSPANS AT NORTH WALL
3) NAIL PROTECT PLUMBING FROM OUTSIDE
4) WIND BRACE N/W CORNER GARAGE TO SHORT
5) 2 HOLDOWNS MISSING N/E CORNER
6) HANGER IN GARAGE MISSING NAILS
7) POST CAP MISSING AT PATIO BEAM TO POST
8) STOPPED INSPECTION TO MANY ITEMS
10/18/2005 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection 1) WORK STILL BEING DONE
10/17/2005 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
Work is not complete enough to inspect.| 950*
1) NOT COMPLETE ENOUGH TO INSPECT
10/13/2005 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection :*
1) NOT COMPLETE ENOUGH TO INSPECT, CANCELLED ON SITE BY J.J. SUPER FOR AMERICA BUILT