Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/05/2005 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 10/26/2005 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1) FINISH TRUSS REPAIR AND BLOCK UNDER HEADER LIVING ROOM |
|
| 10/24/2005 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection :* 1) HV. ROOM TRUSSES, 4 TOTAL FT1 DAMAGED SAG IN FLOOR 2) REPLACE HEADER AT LIVING ROOM BEAM 3) LARGE BEAM HANGERS FILL ALL NAIL HOLES WITH 16D'S REPLACE BENT NAILS |
|
| 09/27/2005 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1) ITEMS ABOVE NOT DONE 2) NEED 3 KNEE BRACES 3) FLOOR NOT SREWED 4) FRONT AND REAR 2ND FLOOR ON TOP OF GLU LAMS, NEED REVISION DETAIL TO TIE DOWN 5) BELLY BAND SHEAR TRANSFER GARAGE |
|
| 09/19/2005 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection :* SEE LAST INSP |
|
| 09/16/2005 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1) FLR NOT FASTENED 2) RAFTER TIE EA END OF GABLE TRUSS 3) 4/3 DETAIL GABLE END BRACES HORIZ AND DIAG BRACES 4) NAIL BELLY BANDS AT 6" OC PERIMETER IN FIELD 5) TIE ALL SHEARS TO TRUSSES AND TO FLR 6) FRONT AND REAR BEARING WALLS NOT TIE 1ST TO 2ND FLR 4' OC 7) NAIL FRIEZE BLKS TO ROOF DECK AND SHEAR PANELS TO ROOF 8) MISSING CROCKET 2ND FLR AT ROOF WEST |