Permit: T05CM04061

Parcel: 141018130


Addresses:

6019 S CEDAR ELM LN


Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T05CM04061

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
12/05/2005 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
10/26/2005 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
1) FINISH TRUSS REPAIR AND BLOCK UNDER HEADER LIVING ROOM
10/24/2005 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection :*
1) HV. ROOM TRUSSES, 4 TOTAL FT1 DAMAGED SAG IN FLOOR
2) REPLACE HEADER AT LIVING ROOM BEAM
3) LARGE BEAM HANGERS FILL ALL NAIL HOLES WITH 16D'S REPLACE BENT NAILS
09/27/2005 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
1) ITEMS ABOVE NOT DONE
2) NEED 3 KNEE BRACES
3) FLOOR NOT SREWED
4) FRONT AND REAR 2ND FLOOR ON TOP OF GLU LAMS, NEED REVISION DETAIL TO TIE DOWN
5) BELLY BAND SHEAR TRANSFER GARAGE
09/19/2005 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection :*
SEE LAST INSP
09/16/2005 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
1) FLR NOT FASTENED
2) RAFTER TIE EA END OF GABLE TRUSS
3) 4/3 DETAIL GABLE END BRACES HORIZ AND DIAG BRACES
4) NAIL BELLY BANDS AT 6" OC PERIMETER IN FIELD
5) TIE ALL SHEARS TO TRUSSES AND TO FLR
6) FRONT AND REAR BEARING WALLS NOT TIE 1ST TO 2ND FLR 4' OC
7) NAIL FRIEZE BLKS TO ROOF DECK AND SHEAR PANELS TO ROOF
8) MISSING CROCKET 2ND FLR AT ROOF WEST