Inspection History Details
Inspection Status: Approved
Inspection History: EXCAVATION/LAYOUT REBAR & ZON
Permit Number - T05CM04017
Inspection Description - EXCAVATION/LAYOUT REBAR & ZON
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/08/2005 | EXCAVATION/LAYOUT REBAR & ZON | Approved | IVRS - Inspection :* | |
11/13/2005 | EXCAVATION/LAYOUT REBAR & ZON | Not ready for Inspection | IVRS - Inspection :* READING REVISION PORCH COLUMNS OK TO GROUT MASONRY PRE-GROUT |
|
10/14/2005 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* 1) PENDING REVISION TO DETAIL 4/A-2 OMITTING #4 DOWELS 48" ON CENTER |
|
10/13/2005 | EXCAVATION/LAYOUT REBAR & ZON | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) WRAP ALL PLUMBING 2) DETAIL 4/A-2 CALLS FOR #4 DOWEL 48" ON CENTER TO EXISTING FOOTING 3) COMPLY WITH DETAIL 9/A-2 COLUMN FOOTING 3-#4 BARS 4) INSTALL SIMPSON HPAHD42 PER PLAN HOLDOWNS 5) PORCH FOOTERS 6/A-2 TO BE DONE AT LATER TIME |