Permit: T05CM04015

Parcel: 11308223A


Addresses:

835 E GLENN ST

Inspection Status: Approved

Inspection History: ELECTRIC - INTERMEDIATE

Date Description Inspector Results Comments
08/26/2005 ELECTRIC - INTERMEDIATE Approved IVRS - Inspection :*
08/25/2005 ELECTRIC - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
NOTE: FLOOR PLAN SHOWS WATER CLOSET AND VANITY SWITCHED
1) SMOKE DETECTOR BEDROOM II IF INSTALLED ON WALL MUST BE 6'-12'' FROM CEILING
08/22/2005 ELECTRIC - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NO WATER TEST DWV SYSTEM
2) NAIL PROTECT ALL PLUMBING UNDER 1'/2"
3) SECURE ALL 90 VENTS THROUGH ROOF
4) NO PRESSURE TEST PEX(?)
5) SMOKE DETECTORS 36" CLEARANCE FROM REGISTERS
6) BLOCK REGISTERS 3-SIDES
7) TERMINATE HOME RUNS IN PANEL
8) FIRE STOP DROPPED CEILING
9) STOPPED INSPECTION