Inspection History Details
Permit: T05CM03977
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/07/2005 | FRAMING | Approved | IVRS - Inspection :* | |
| 10/06/2005 | FRAMING | Partial Approval | IVRS - Inspection :* 1) ITEM 03050 NOT REQUIRED-NO GAS-ALL ELECTRIC 2) PARTIAL FOR HOLDOWNS NOT INSTALLED |
|
| 10/05/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SEAL LATH PENETRATION EAST WALL 2) FHA STRAPS MISSING NAILS 3) FIREBLOCK PLUMBING CHASE AT KITCHEN 4) PLUMBERS TAPE NOT ALLOWED FOR ABS SUPPORT 5) OVER SPAN AT GARAGE SHEAR WALL 6) INSTALL FHA STRAPS DBL TOP PLATE MASTER CLOSET 7) F3 TRUSSES MISSING BLOCKS 8) SHIM HEADERS WHERE NEEDED 9) UNTREATED STAIR STRINGER IN CONTACT WITH CONCRETE 1) DWV'S HAVE NO WATER TO 2ND FLOOR 11) FIRE BLOCKS MISSING AT LAUNDRY 12) HANGER IN LAUNDRY MISSING NAIL 13) RIDGE BLOCK CRACKED 14) OVERSPAN UPSTAIRS MIDDLE BEDROOM NORHT WALL 15) ENSURE ALL BEDROOMS AND SMOKE DETECTORS ARC ON ARC FAULT CIRCUITS AND WATER HEATER HAS A DISCONNECT 16) STOPPED INSPECTION |