Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T05CM03963

Parcel: 136141070

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T05CM03963

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
01/18/2006 FRAMING Approved IVRS - Inspection :*
01/13/2006 FRAMING Not ready for Inspection IVRS - Inspection :*
01/12/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) FILL ALL NON DIAMOND HOLES IN TRUSS HANGERS
2) HAVE ENGINEER CHECK EAST END TRUSS K-4
3) MOVE ACCESS HATCH
4) NAIL STRAPS BUILT UP POSTS GARAGE AND TOP PLATE AT PANEL
5) NO FURNACE DISCONNECT