Permit: T05CM03948

Parcel: 141018670

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T05CM03948

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
12/01/2005 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
11/30/2005 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NO PANEL INSTALLED
2) LARGE SHEAR PANELS TO SHORT NOT NAILED TO ROOF
3) SHIM ALL 3 PT BEARING
4) H2.5 ALL FOUR CORNERS ROOF TRUSSES
5) TIE SHEAR TO GABLE TRUSSES 2ND FLOOR
6) FILL ALL NAIL HOLES IN LARGE HANGERS WITH 16D'S COMMONS
7) TRUSS AT STAIR 1ST FLOOR GUSSET PLATE LOOSE
8) FRIEZE BLKS NOT NAILED TO ROOF