Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T05CM03948
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/01/2005 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
11/30/2005 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NO PANEL INSTALLED 2) LARGE SHEAR PANELS TO SHORT NOT NAILED TO ROOF 3) SHIM ALL 3 PT BEARING 4) H2.5 ALL FOUR CORNERS ROOF TRUSSES 5) TIE SHEAR TO GABLE TRUSSES 2ND FLOOR 6) FILL ALL NAIL HOLES IN LARGE HANGERS WITH 16D'S COMMONS 7) TRUSS AT STAIR 1ST FLOOR GUSSET PLATE LOOSE 8) FRIEZE BLKS NOT NAILED TO ROOF |