Permit: T05CM03937

Parcel: 12901044C


Addresses:

1940 E BROADWAY BL


Inspection Status: Approved

Inspection History: ENGINEERING - FINAL

Permit Number - T05CM03937

Inspection Description - ENGINEERING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
01/19/2007 ENGINEERING - FINAL Approved Contractor completed punch list. Hold Grading permit until fuel station is completed.
12/13/2006 ENGINEERING - FINAL Partial Approval OKAY FOR C OF O PER INSPECTION COPY
COMPLETE ITEMS 5,6,10, AND 14
12/01/2006 ENGINEERING - FINAL Denied Contractor needs to complete for Temp C of O:
1- Complete all HC items. (ramps, trucated domes)
2- Complete all public access items or fence off.
3- Seperate all construction activity from public access.
4- Seperate all construction debris from public access.
5- Remove form pins from rear drainage channel.
6- Address ponding issue west side of building. (around existing building)
7- Complete all work along Norris or fence off.
8- Submit phased grading plan. Seperate gas station from store.
9- Clean all wash out from around building.

For final C of O and Grading also complete:
1- Stabilize all areas disturbed by construction.
2- Complete all basin work.
3- Clean parking area. (all)
4- Clean Norris.
5- Complete all construction around outside of building.
6- Remove all construction debris.
7- Remove all BMP's.
8- Remove all port-a-pottys.
9- Fence off all work for gas station. No equipment or materials outside of fencing.
10- Remove wood forms from scuppers.
11- Complete all striping.
12- Stabilize alley south of 220 Norris. (cold patch)
13- Install gates on trash enclosure.
14- Submit all red lines to review engineer.
This is not a final punch list, other items may need to be addressed.