Inspection History Details
Inspection Status: Approved
Inspection History: REINFORCED MASONRY PRE-GROUT
Permit Number - T05CM03937
Inspection Description - REINFORCED MASONRY PRE-GROUT
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/16/2007 | REINFORCED MASONRY PRE-GROUT | Approved | ||
09/19/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* DETAILS GSN, S1.1A, S1.2, S3.1S, S3.2 PARTIAL @ 10-B.8-A.5 @ TOPOUT |
|
09/15/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* PARTIAL @ GRIDLINE 10 - B.7 - E.1 16'3" - 20' - 3" A.F.F.E |
|
09/14/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
09/13/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* F - 8.4-9.0 @ TOP OUT 10 - C.5-E.2 DETAILS GSN. S1.1A, S1.2, S3.1A, S3.2, S4.1 |
|
09/12/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | PARTIAL @ L-5 ABOVE | |
09/11/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | GRIDLINE 10- B.8-D.7 @ 8'0" @ 12'0" A.F.F.E A- 6.1 - 8.0 @ 4'0"-8'0" A.F.F.E DETAILS GSN: S1.1A, S1.2, S3.1A, S3.2 |
|
09/08/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* GRIDLINE 10 - C.5-I.2 @ 4'0" - 8'0" A.F.F.E 10 - B.8 - C.5 @ 8'0"-12'0" A.F.F.E DETAILS GSN & SHEETS S1.1A, S3.1A, S3.2 |
|
09/07/2006 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | IVRS - Inspection :* | |
09/06/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* GRIDLINE 6-A THRU B TOPOUT DETAIL 3 ON S3.2 GRIDLINE 10-B THRU C.J |
|
09/06/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | GRIDLINE B 8.3-10 @ TOP OUT 10 B-B.8 @ TOP OUT DETAIL GSN + S1.1A, S1.2, S3.1A, S3.2 |
|
09/05/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* A - 4.5-6.0 TOPOUT 6 - A.B 19'4"-23'8" A.F.F.E B - 8.3-10 10.00/B2 B.8 14'4"-18"-8" A.F.F.E DETAILS S0.2, S1.1A, S1.2, S3.1A S3.2 & S4.1 |
|
08/31/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* UR - B/8.3-10 @ 12'0" - 16'00" A.F.F.E DETAIL S0.2 S1.1A, S1.2, S3.1A, S3.2 10/B-B.8 @ 12'0" - 16'00" A.F.F.E DETAIL S0.2 S1.1A, S1.2, S3.1A, S3.2 A/6-4.5 @ 16'8" - 20'8" A.F.F.E DETAIL S0.2 S1.1A, S1.2, S3.1A, S3.2 6/A-B @ 12'8" - 16'8" A.F.F.E DETAIL S0.2 S1.1A, S1.2, S3.1A, S3.2 |
|
08/30/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* PARTIAL GRIDLINE A 4.3-6.0 16'-4" 20'8" A.F.F.E 3 A/A.2 A2.2F A/3.0-4.3 TOP OUT 6/A-B 12'-8" 16"-4" A.F.F.E B/6.-8.3 TOP OUT DETAILS IN SHEETS SO.2, S1.1A, S1.2, S3.1A, S3.2 |
|
08/29/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* GRIDLINE B - 6.2 THRU 8.2 DETAIL 20/A2.2F GRIDLINE A - 3 THRU CJ DETAIL S3.2 5 MASONRY/SCREEN WALL 10' 0" APPROVED 1ST LIFT 4'-0" |
|
08/28/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* PARTIAL B: B.3 - 6.3 @ 12'-01' ABOVE F.F.E PARTIAL B: 10 - 8.3 @ 0-3'4' ABOVE F.F.E DETAILS A2.2F, SO.2, S1.1A, S1.2, S3.1A, S3.2 SECOND DETAINING WALL GRIDLINE A: 6-8 2'0" - 1'8" AFFE |
|
08/25/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
08/24/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* PARTIAL @ UNDER SPC. INSP. SHEET R156-175 ON SAME DAY. DETAIL S1.1A, S1.1B, S3.1A, S3.2 |
|
08/23/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* GRIDLINE 10/E.9-E.2 @ TOP OUT GRIDLINE B/6.2-8.2 --- 11'-4" H DETAIL 20/SHEET A2.2F 11'-4" A.F.F.E |
|
08/22/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* NOTE: GRIDLINE F/9.2 - 10.0 @ 16'4" - 20'4" AF.FE 10/E.2 - F.O @ 16'4' - 20'4" A.F.F.E B.O/2.3-3.0 @ 20' TOP OUT 3.0/A.5-B.0 @ 20' TOP OUT |
|
08/21/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* LINE A/3-6 @ 9'; 16' LINE FROM 10/E TO F/8.3 |
|
08/18/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* TOP LINE F/1-8.3; STEMS @ EAST LANDING DOCK OK 8' @ LINE B/6-8.2 |
|
08/17/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* F/2.0-8.3 @ 23'; 10/F.0-G.2 @ 16' |
|
08/16/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 19' F/2-8; 17' F/9-10; 12' 10/F-E |
|
08/15/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 8' LINE 10/E-F; 14' LINE F 8.3-10; 16' LINE F/2-7 TOP @ 1/F CORNER; TOP LINE B/1.8-3 OK WHEN SPECIAL INSP. CONFIRMS; 20' LINE/A-B; 8' LINE B 6-8.2 |
|
08/14/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* B/1.7-2.7 @ 20' AND B 6-8.3 @ 4' LINE F PORTIONS OK TO 16' NEED TO SEE REPAIRS TO SHORT SPLICES TOMORROW. |
|
08/11/2006 | REINFORCED MASONRY PRE-GROUT | Denied | IVRS - Inspection : See detailed listing on site.| 999* LINE F 12' TO 16' LAP SPLICED DO NO MEET PLANS ARE INCONSISTENT IN LENGTH. REFER TO ENGINEER. |
|
08/10/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* TOP LINE 1/D-5 AND B/1-1.8 |
|
08/09/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
08/08/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1. TO ROOF LINE GRID LINE 1 OK TO GROUT. 2. SPLICE TO ADJACENT CELL FOR TOO SHORT DOWELS LINE 1/ C.-C.5 |
|
08/07/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
08/04/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 20' F/2.1 TO 1/D.5; 16' B/1-1.8 A. REMOVE EXCESS MORTAR FROM BOTTOM OF BEAM LINE B 1.8-3.1 B. DO NOT ROD GROUT. BE CAREFUL NOT TO MOVE VERTICALS AFTER GROUT POURED OR IT LOOKS LIKE RODDING. |
|
08/03/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 16' F/2.9 TO 1/E.5; TO BOTTOM OF BEND BEAM 1/E.5 TO 1/C.5 |
|
08/01/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* B/1 TO B/1.8 (9'4" TO 13') F/1.1 TO 3/.6 TO 9' |
|
07/31/2006 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | IVRS - Inspection :* CANCELLED BY CONTRACTOR |
|
07/26/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* EAST WALL B/1 TO F/1 @ 12' |
|
07/25/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 8' LINE 1/ E CLOCKWISE TO LINE B/3 |
|
07/24/2006 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | IVRS - Inspection :* | |
07/21/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 12' LINE F/8.3-4.3; 1ST LIFT DOCK WALL LINE A; 4' LINE A/3.5-6', 4' LINE 6/A-B REMEMBER NO HORIZONTAL LAP SPLICES WITHIN 8' OF MCJ 1 EXCEPTION MADE FOR TODAY'S POUR ONLY! |
|
07/20/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 4' LINE LINE 10 B-D; 8' LINE F/4-10 |
|
07/19/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1. INSTALL STEEL AND TIED LINE F PER KEYNOTE 5 OR RFI ENGINEER KEYNOTE 5 IS ISSUE @ L4 JAMBS. 2. 4' LINE B/1-3, LINE 3/A-B, LINE A/3-3.5 |
|
07/18/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1. LINE 1 4'/A-C 2. 4' LINE 10/D-F |
|
07/17/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 4' LINE 1/C-F |
|
07/14/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* F/1 THROUGH F/10 0' TO 4' |
|
07/13/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* GRIDLINE F 1 THRU 10 0'-0" -- 4'0" DETAIL S1.2 - 1 |
|
07/12/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* GRIDLINE F 9.1 THRU 10 1 THRU 2.1 |
|
07/11/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* GRIDLINE F 4.3 THRU 8.3 F.F 0-4'0" DETAIL S1.2-1 |