Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
Permit Number - T05CM03900
Inspection Description - BUILDING - FINAL
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/13/2006 | BUILDING - FINAL | Approved | IVRS - Inspection :* | |
| 09/27/2006 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) TIGHTEN AND BREAK OFF SMALL BOLT ON ANTI-SIPHON HOSE BIBS 2) A/C WIRES INCORRECTLY COLOR CODED 3) A/C DISCONNECT OVER FUSED 4) MUST HAVE MINIMUM 36" STOOP REAR SLIDER WIDTH OF OPENING 5) INSTALL PLASTIC BUBBLE COVERS EXTERIOR RECEPTACLES 6) MUST HAVE 6" CLEARANCE FURNACE FLUE TO COMBUSTIBLES OR SWITCH TO DBL WALL ALL THE WAY THROUGH ROOF 7) CAULK AROUND BASE OF TOILET 8) INSTALL RANGE CONNECT TO GAS OR ELECTRIC-PLUG GAS LINE IF NOT USING 9) 03040 WATER-NEED VERIFICATION OF INSPECTION APPROVAL 10) MUST HAVE 6" CLEARANCE IN FRONT OF FURNACE 11) NEED PERMIT PORCH EXTENSION 12) CANNOT HAVE ELECTRIC RECEPTACLE IF KITCHEN COUNTER OVER HANG EXCEEDS 6" |