| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/22/2006 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 03/20/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. NEED LSI FOR DEN ENTRY CORNER N/E |
|
| 02/06/2006 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1) CHECK ALTERNATE H.D.'S AT INTERMEDIATES |
|
| 02/05/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) COMPLETE HD'S 2) NAIL PROTECT PLUMBING 3) H2.5'S MISSING S.W. CORNER 4) CLIPS NOT NAILED EAST SIDE 5) SHIM 3 POINT BEARING TRUSSES |