Inspection History: BUILDING - FINAL
Permit Number - T05CM03878
Inspection Description - BUILDING - FINAL
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/01/2006 | BUILDING - FINAL | Approved | IVRS - Inspection :* | |
| 10/26/2006 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) REMOVE RECEPTACLE AND CAP OUTLET UNDER KITCHEN BAR 2) ISLAND REQUIRES OUTLET 3) REMOVE BOND JUMPER FROM NEUTRAL TO GROUND BUS BARS IN SUB PANEL 4) BEDROOMS 2 & 3 REQUIRE ARC FAULT PROTECTION 5) CLAMP DISHWASHER DRAIN TO BOTTOM OF COUNTER TOP 6) REMOVE ANY GAS WHIPS NOT CONNECTED TO APPLIANCES 7) WATER HTR SEDIMENT TRAP MUST BE AFTER VALVE 8) BOND HVAC DUCT AROUND BOOT 9) CLAMP A/C WHIP DISCONNECTS 12" |
|
| 10/23/2006 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NO ACCESS |