Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/21/2006 | FRAMING | Approved | IVRS - Inspection :* | |
| 03/27/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) LOOSE #12 ROMEX 2ND FLOOR (ROOF RECEPTACLE) ? 2) NEED DWV TEST 3) VENT FOR TUB TO BE 6" ABOVE FLOOD RIM BEFORE GOING VERT 4) SUPPORT DROP CEILING AT TOP OF STAIR 2ND FLOOR 5) OVER SPAN 2ND FLOOR TUBS TWO 6) #8 FOR ROOF UNIT 7) BANG PLATE CONDENSATE TOP PLATE 2ND FLOOR 8) BACKING AT TUB SIDE (NORTH TUB) 9) MISSING 5, HTT16 H.D.'S 10) MISSED #3 SHEAR AT FRONT ENTRY, #1 ABOVE #3 AT STAIR HTT 16 MISSING 11) NO DETAIL FOR PORCH POST 2ND FLOOR |
|
| 03/20/2006 | FRAMING | Not ready for Inspection | IVRS - Inspection :* HOLES THRU OUT ON WATER BARRIER FOR STUCCO |