Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
Permit Number - T05CM03827
Inspection Description - BUILDING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/02/2006 | BUILDING - FINAL | Approved | IVRS - Inspection :* | |
07/27/2006 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) WRONG APPLICATION OF FIXTURE FOR ROUGH IN BOX IN GARAGE 2) SHEETROCK SCREWS ARE UNACCEPTABLE FASTENERS FOR USE WITH ELECTRICAL BOXES 3) PROVIDE LADDER FOR ATTIC INSPECTION |
|
07/26/2006 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) COMPLETE STUCCO 2) COMPLETE PRIOR LIST |
|
07/24/2006 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) CUT CLEANOUTS TO GRADE 2) EXTERIOR GRADE MUST SLOPE AWAY FROM HOUSE 3) WRONG APPLICATION OF LUMINARIE IN GARAGE 4) SINGLE WALL FLUE REQUIRES 6" CLEARANCE TO COMBUSTIBLES 5) STOPPED INSPECTION |