Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
11/23/2005 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
11/21/2005 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) CLIP STUDS S.E. CORNER AND CONTINUE KINGS ALL THE WAY DOWN
2) CLIPS MISSING NAILS
3) LADDER NOT SECURED
4) OVERSPAN N.W. CORNER GARAGE, S.W. CORNER
5) PROVIDE 1/8" GAP AT ALL END AND EDGES ON ROOF SHEATHING AND MUST SPAN TWO BAY 3 MEMBERS