Inspection History Details
Inspection Status: Approved
Inspection History: EXCAVATION/LAYOUT REBAR & ZON
Permit Number - T05CM03804
Inspection Description - EXCAVATION/LAYOUT REBAR & ZON
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/18/2005 | EXCAVATION/LAYOUT REBAR & ZON | Approved | IVRS - Inspection :* | |
| 08/29/2005 | EXCAVATION/LAYOUT REBAR & ZON | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SECURE ALL WIRES WITHIN 6" OF BOX. OUTER INSULATION MUST EXTEND AT LEAST 1/2" INTO BOX 2) NEED STRUCTURAL DRAWINGS FOR BEARING OVER WEST 4'0 X 4'0 WINDOW 3) SIDING NEEDS TO BE FASTENED 8" OC AT EDGES AND 12" OC FIELD 4) EXPOSE FOOTING IN TWO PLACES TO SHOW BEARING 12" INTO NATIVE SOIL |