Inspection History: EXCAVATION/LAYOUT REBAR & ZON

Permit Number - T05CM03804

Inspection Description - EXCAVATION/LAYOUT REBAR & ZON

Inspection Status - Approved

Date Description Inspector Results Comments
10/18/2005 EXCAVATION/LAYOUT REBAR & ZON Approved IVRS - Inspection :*
08/29/2005 EXCAVATION/LAYOUT REBAR & ZON Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) SECURE ALL WIRES WITHIN 6" OF BOX. OUTER INSULATION MUST EXTEND AT LEAST 1/2" INTO BOX
2) NEED STRUCTURAL DRAWINGS FOR BEARING OVER WEST 4'0 X 4'0 WINDOW
3) SIDING NEEDS TO BE FASTENED 8" OC AT EDGES AND 12" OC FIELD
4) EXPOSE FOOTING IN TWO PLACES TO SHOW BEARING 12" INTO NATIVE SOIL