Permit: T05CM03788

Parcel: 140382730


Addresses:

5969 E CHAUCERS DR

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
11/16/2005 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
10/27/2005 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) OVERSPAN AT REAR SHEAR
2) GREEN PLATE MISSING AT BOTH COLUMNS
3) TIE DOWN HDR AT BACK COLUMN
4) TIE BACK GABLE DOWN TO COLUMN
5) TIE GABLE DOWN TO FRONT COLUMN
6) H2.5 AT ENTRY
7) TIE GABLE DOWN ABOVE FRONT WINDOW
8) TIE DOWN DBL TOP PLATE AT GARAGE SHEAR
9) SHIM 3 POINT BEARING TRUSSES