Inspection History Details
Permit: T05CM03771
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/17/2005 | FRAMING | Approved | IVRS - Inspection :* | |
| 10/14/2005 | FRAMING | Partial Approval | IVRS - Inspection :* 1) NO GAS TEST 2) NEXT FAILURE WILL REFEE |
|
| 10/13/2005 | FRAMING | Partial Approval | IVRS - Inspection :* | |
| 10/11/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) ANCHOR BOLTS REQUIRED WITHIN 12" OF PLATE SPLICE GARAGE 2) #6 SHEARWALL NOT NAILED AT TOP PLATE IN GARAGE 3) MBR LTT20 NUT LOOSE 4) NO GAS PRESSURE TEST |
|
| 10/06/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SHEAR BLOCKS IN GARAGE 2) 1" CLEARANCE TO COMBUSTIBLES AROUND WATER HEATER B-VENT 3) BANG PLATE ON 1 1/2" VTRI AT KITCHEN 4) TIGHTEN ALL A.B. AND HOLDOWNS 5) BLOCK ROOF SHEATHING AT KITCHEN HOOD VENT 6) NAIL PROTECT WIRES THROUGHOUT 7) FIREBLOCK MASTER BATH CHASE AT EXTERIOR WALL 8) OPEN DRAIN ON MECH PAN 9) SECURE TRAP ARM IN ?/BATH 10) NO GAS PRESSURE |