Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/15/2006 | BUILDING - FINAL | Approved | IVRS - Inspection :* | |
| 09/13/2006 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) COMPLY WITH PREVIOUS INSPECTION |
|
| 09/01/2006 | BUILDING - FINAL | Partial Approval | IVRS - Inspection :* NEED INSULATION CERTIFICATE |
|
| 08/31/2006 | BUILDING - FINAL | Partial Approval | IVRS - Inspection :* 1) SMOKE DETECTORS NOT ON ARC FAULT CIRCUIT |
|
| 08/02/2006 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. BEDROOM OUTLETS NOT ARC FAULT PROTECTED 2. PROVIDE CERTIFICATES |
|
| 07/28/2006 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) WATER HEATER TPR LINE MUST BE HARD PIPED 3/4" 2) SECURE DISHWASHER DRAIN HOSE HIGHEST POINT UNDER CABINET 3) MASTER BEDROOM OUTLETS NOT ARC FAULT PROTECTED 4) ALL BEDROOMS NOT ARC FAULT PROTECTED |