Permit: T05CM03770

Parcel: 12216285D


Addresses:

1717 N BAXTER DR

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
04/12/2006 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
03/30/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) PER ALTERNATE SHEARWALL DETAIL 8D COMMONS 6" ON CENTER AND 12" IN FIELD AT GARAGE ENTRY
2) PER BRACED WALL DETAIL 48" 8D COMMONS 6" ON CENTER 12" IN FIELD ALL JOINTS NAILED BRACED WALL NOTE 4
3) WINDOW INSTALLED BRACED NORTH WEST CORNER KITCHEN
4) RETRO FITS REQUIRED PAH042 NAILED INTO TRIMMERS MUST NAIL INTO 2 KING STUDS
5) EXPOSE A3.5 PER WOOD JOIST DETAIL GARAGE FRONT ENTRY WALL 4-16D COMMONS EACH STUD AT LEDGER GARAGE WEST WALL
6) RETRO FITS REQUIRED 24" BRACED WALL BEDROOM 2 NORTH WALL
7) PROVIDE SAFE ACCESS TO ROOF