Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/22/2006 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* | |
| 09/21/2006 | ELECTRIC - FINAL | Partial Approval | IVRS - Inspection :* 1) MASTER BATHROOM GFI'S DO NOT TEST 2) USE APPROVED COVERS ON LIGHTS OVER SHOWER 3) UPSTAIRS OK 4) NEED VACUUM BREAKERS ON HOSE BIBS 5) PROVIDE INSPECTION OF SEPTIC SYSTEM |
|
| 09/11/2006 | ELECTRIC - FINAL | Denied | 1) REMOVE TEMP POWER RECEPTACLE 2) ADD BOX EXTENSION AND BUBBLE COVER TO REAR AND FROM RECEPTACLES 3) ALL GARAGE RECEPTACLES UNDER 7' FEET MUST BE GFI 4) SECURE FLEX TO WATER HEATER 5 T/P LINE TO END BETWEEN 6 + 12" OF FINAL GRADE 6) INSTALL PAD UNDER COMPRESSOR UNIT 7) NEED PERMANENT ADDRESS VISIBLE FROM STREET 8) FINAL GRADE MUST SLOPE AWAY FROM HOUSE 9) MASTER BATHROOM GFI'S DO NOT TEST 10) USE APPROVED COVERS ON LIGHTS OVER SHOWER 11) CAULK TOILETS TO FLOOR 12) RECEPTACLE COVERED IN MASTER BEDROOM 13) RECEPTACLE LEFT OF SINK-INOPERABLE 14) INSTALL RECEPTACLE IN ISLAND 15) RECEPTACLES IN NOOK-INOPERABLE 16) STOPPED INSPECTION-DID NOT DO 2ND FLOOR |