Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING PRE-SLAB
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/28/2005 | BUILDING PRE-SLAB | Approved | IVRS - Inspection :* | |
| 10/26/2005 | BUILDING PRE-SLAB | Not ready for Inspection | ||
| 10/24/2005 | BUILDING PRE-SLAB | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PROVIDE PROPERTY PINS ON ALL 4 CORNERS OF LOT 2) YOU MUST REQUEST THROUGH THE COMPUTER ALL REQUIRED INSPECTIONS. YOU MUST REQUEST A ROUGH PLUMBING INSPECTION FIRST THEN AN EXCAVATED, LAYOUT PRE-SLAB AND UFER INSPECTION 3) YOU MUST PROVIDE A 10 FOOT DRAIN WASTE AND VENT WATER TEST 4) EXPOSE ALL PLUMBING UNDER SLAB 5) INSTALL ALL UNDERSLAB "P" TRAPS 6) SEVERAL LEAKS ON ROUGH PLUMBING 7) REINFORCING STEEL MUST BE 3" FRO SOIL 8) PLUMBING IS FROM FLAT TO REVERSE PITCH MUST HAVE 1/4" PER FOOT PITCH 9) HPHD22 HOLDOWNS NOT INSTALLED 10) MARK LOCATIONS OF ANCHOR BOLTS FOR BRACED WALL PANELS 11) PROVIDE FOOTERS WITH STEEL PER 2/S-1 |