Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/05/2007 | FRAMING | Approved | IVRS - Inspection :* | |
| 06/04/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) COMPLETE ITEMS 2, 3, 8 & 9 FROM PREVIOUS 2) WINDOW IN LAUNDRY MEETS MAKE UP AIR REQUIREMENT |
|
| 03/20/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PROVIDE WATER TEST ROOF TOP DWV 2) NAIL PROTECT THROUGHOUT 3) TERMINATE EXHAUST FAN TO EXTERIOR MISSING HIGH/LOW COMBUSTION DUCTS WATER HEATER MISSING EXHAUST FAN LAUNDRY ROOM 4) SECURE HOMERUNS 5) SECURE MAIN FEEDERS WEST WALL 6) PROVIDE 12" CLEARANCE ALL PEX FROM CANS 7) SUBMIT AS BUILT FOR CHANGES NOT TO PLAN 8) REPAIR OVERKNOTCH DBL TOP PLATE LAUNDRY ROOM 9) GROUT TUB SHOES 10) BLOCK REGISTER BOOTS 3 SIDES |
|
| 03/15/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) GATE LOCKED 2) NO ANSWER AT DOOR 10:20 AM |
|
| 09/13/2006 | FRAMING | Not ready for Inspection | IVRS - Inspection :* 1) INSTALL LATHE |
|
| 08/16/2006 | FRAMING | Not ready for Inspection | IVRS - Inspection :* |