Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T05CM03726

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
12/15/2005 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
12/12/2005 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) WRONG SIZE GUSSET PLATE ON ? 8 5" X 8" REQUIRED
2) NO HANGER EAST WALL HALF TRUSS
3) SHEARWALL NOT PER PLAN 6/DT2 KITCHEN
4) STOPPED INSPECTION, TOO MANY ITEMS MISSING FROM PREVIOUS INSPECTION
12/06/2005 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) INSTALL ALL RAT RUNS
2) TRUSS B-3 AT JOINT 8 WRONG SIZE GUSSET PLATE, TRUSS MEMBER IS DAMAGED
3) SHIM ALL 3 PT BEARING
4) INSIDE END TRUSS-NO HANGER NAIL TO WALL
5) HALF TRUSS ON EAST GARAGE WALL NO HANGER
6) LOOSE GUSSET ON B-4 TRUSS GARAGE
7) SHEAR TRANSFER FOR KITCHEN NOT PER PLAN
8) LEDGER ABOVE LAUNDRY ROOM NEEDS 16D COMMONS
9) MISSING HANGERS S/E BEDROOM 2ND FLOOR
10) CANNOT STRIP AT REAR GABLE
11) SOLID VERT STUDS AT BEAM SUPPORT 1ST AND 2ND FLOOR LIVING ROOM
12) #5 SHEAR TIE TO GABLE TRUSS NORTH 2ND FLOOR SHEAR TO ROOF
13) KITCHEN SHEAR WEST WALL NAIL TO ROOF 8D 6" ON CENTER
14) WALKED ROOF-ALL OK BUT KITCHEN SHEAR
15) WHAT ELEVATION IS THIS HOUSE ?
11/21/2005 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection :*