Permit: T05CM03718

Parcel: 134083240

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
09/07/2006 PLUMBING - FINAL Approved
09/06/2006 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
09/05/2006 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
ALL FIXTURES TO BE FUNCTIONAL
EXTERIOR VENT THRU ROOF TO BE PAINTED IN EXPOSED LOCATION ON ROOF.
08/15/2006 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1. SHALL USE LONG RADIUS FITTING FOR STUDDOR VENT BRANCH BELOW FLOOD RIM OF FIXTURE.
2. MAKE WATER TIGHT ALL FIXTURES.
3. INSTALL SHOWER DRAIN STRAINER & LAUNDRY BOX ESCUTION & REFRIGERATOR BOX ESCUTION.
4. PROVIDE 2-HOLE CLAMP FOR HIGH LOOP OF DISHWASHER DRAIN HOSE & CLAMPS FOR DISPOSAL CONNECTION.
5. PROVIDE PERMANENT LABEL FOR NON-BONDED PLASTIC WATER PIPING.
6. PROVIDE 90 DEG. DOWN TERMINATION OF WATER HEATER T&P
7. PROVIDE LOCKHOLE COVERS AT SINK EXTRA HOLE.
8. PROVIDE TAPPED CLEANOUT PLUGS -- CLEANOUT COVERS & MACHINE SCREWS.
08/09/2006 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
THIS INSPECTION FOR FINAL CONNECTION OF YARD WATER OK
08/08/2006 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
THIS INSPECTION FOR YARDWATER TIE-INS
SHALL PROVIDE CORRECT TRANSITION FROM PLASTIC TO COPPER. SHALL HAVE PIPING ON FIRM BEDDING.