Permit: T05CM03718

Parcel: 134083240

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
02/21/2006 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
WATER TEST THRU ROOF WASTE & VENT OK
WATER PIPING OK
02/17/2006 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
SEE NOTES ABOVE & COMPLY
ALL VENT PIPING BELOW FLOOD RIM OF FIXTURE TO BE LONG RADIUS DRAINAGE FITTINGS, ALL DRAINAGE PIPING TO BE LONG RADIUS DRAINAGE FITTINGS.
02/14/2006 PLUMBING - INTERMEDIATE Cancelled CANCELLED PER CONTRACTOR ERIC #808-9906
02/14/2006 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
02/09/2006 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
PROVIDE TEST ON PAN DRAIN FOR UPSTAIRS WASHING MACHINE PROVIDE BACKING & SUPPORT TUB & SHOWER DRAINS.
1. PROVIDE 3" UPPER TERMINAL CLEANOUTS AS REQUIRED PER 94 UPC -- SUPPORT HORIZONTAL DRAINAGE & UNIT AT 4' INTERIORS FOR PLASTIC PIPING.
2. PROVIDE SEPARATION OF HOT & COLD TUBING FOR WATER AND SUPPORT
3. PROVIDE CORRECT TRANSITION FOR PVC TO ABS PIPING OR PROVIDE PVC WASTE & OVERFLOW KITS FOR TUBS. GREEN GLUE NOT IN CORRECT TRANSITION.
4. EXPOSE ALL WASTE & VENT PIPING FOR INSPECTION
5. VENT KITCHEN PER PLAN WITH WATER TEST