Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/06/2006 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
| 09/05/2006 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. CALL IN ALL INSPECTION THAT ARE NOT APPROVED FOR PLUMBING ON YOUR PERMIT CARD. 2. PROVIDE 2-HOLE CLAMP FOR HIGH LOOP AT DISHWASHER DRAIN. 3. PROVIDE SIGNAGE PERMANENT FOR NO BONDING AT WATER PIPING IN ELECTRICAL PANELS. 4. EXTERIOR VENTS TO BE PAINTED ON ROOF. 5. ALL CLEANOUTS & PLUGS TO BE PROPERLY TERMINATED 6. PVC PIPING REQUIRES PVC TRAP ADAPTERS, USE LIKE FOR LIKE MATERIALS. 7. CORRECTLY TERMINATE BACKWATER VALVE RISER. |
|
| 08/31/2006 | PLUMBING - FINAL | Cancelled | ||
| 08/31/2006 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* |