Permit: T05CM03717

Parcel: 134083230

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Permit Number - T05CM03717

Inspection Description - PLUMBING - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
02/24/2006 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
02/23/2006 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
WATER TEST WASTE & VENT THRU ROOF OK
1. PROVIDE CORRECT SUPPORT FOR ALL TUB & SHOWER VALVES
2. PROVIDE TEST ON WATER PIPING & PROVIDE SEPARATION OF HOT & COLD TUBING
3. ALL HORIZONTAL PLASTIC DWV PIPING SHALL BE SUPPORTED AT 4' INTERVALS
4. PROVIDE BRASS WATER RESISTANT SCREWS TO SECURE ALL DEVICES IN WET AREAS (CLOSET FLANGES ETC)
02/21/2006 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*