Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
04/05/2007 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
04/03/2007 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
SHOWER PANS OK
NORTH CLOSET FLANGE UPSTAIRS SHALL BE SECURED PROPERLY
01/05/2007 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
SECURE SHOWER HEAD W/TWO SCREWS
OK TO COVER
RECALL 3035 FOR SHWR PANS
01/03/2007 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. CORRECT LEAKS AT STEM WALL AND AT UPSTAIRS LAV
2. HAVE TEST ON PRIOR TO INSPECTION
3. LAV TRAP ARM 42" MAX FROM WEIR OF TRAP TO VENT
4. SWEEPS REQUIRED ON VENTS BELOW FLOOD RIM
5. 18" OF METALLIC PIPING BETWEEN SWEAT VALVES AND PEX TUBING.
6. CHECK WATER PIPE SIZING AND HOSE BIBS