Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T05CM03687
Inspection Description - FRAMING
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/16/2005 | FRAMING | Approved | IVRS - Inspection :* | |
| 12/14/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) ELECTRIC BOX DETACHED FROM WALL KITCHEN 2) SEAL ALL STAPLE PENETRATIONS LATHE 3) NO TEST DWV 4) INSTALL BANG PLATES ELECTRIC WITHIN 1 1/4 OF STUD FACE 5) INSTALL BANG PLATES PLUMBING WITHIN 1 1/2 OF STUD FACE 6) STOPPED INSPECTION |
|
| 12/09/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NO PLANS/PERMIT |
|
| 12/06/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NO PLANS/PERMIT 2) NO TEST DWV; POTABLE H20 3) STOPPED INSPECTION |