Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T05CM03685
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/26/2006 | FRAMING | Approved | IVRS - Inspection :* | |
01/24/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) 2ND FLOOR LAUNDRY SEE WRITING ON FLOOR 2) 2ND FLOOR ROMEX CUT 3) REPAIR OVEN VENT NEED HEADER 4) 2 1/2" DIAMETER A.B.'S AT SHEARWALL NEXT TO STAIR 5) OVERSPAN 1ST FLOOR BATH, BLK DUCT CEILING 6) NO DWV TEST 7) RANGE WIRE NOT CONNECTED TO BOX 8) MISSING NAILS IN STAIR HEADER HANGER |
|
01/23/2006 | FRAMING | Partial Approval | IVRS - Inspection :* 1) FIREBLOCK TUBS 2) REATTACH RAT RUN TRUSSES OVER LAUNDRY TO STRAIGHTEN BOTTOM CORDS 2) REROUTE STOVE WIRE 3) SECURE CEILING LIGHT IN LAUNDRY 4) ADD RECEPTACLE S.E. CORNER MASTER BEDROOM 5) PURPOSE OF WIRE N.E. CORNER MASTER BEDROOM ? 6) DRYER BOX THICKER THAN WALL |